SPD Type 1+2+3 12.5kA Three-Stage — LT-T15/B+C

LT-T15/B+C — B+C Combined SPD for Single-Stage Protection

A B+C combined device covering Type 1, Type 2 and Type 3 in one module, with four selectable Iimp steps from 6.25 to 25kA and a 1.25kV protection level. Designed so a main board can be protected to all three classes without a co-ordination calculation between separate stages.

Model

✓

LT-T15/B+C SPD product photo

LT-T15/B+C Combined Three-Class Surge ProtectorType 1+2+3 · Iimp 6.25–25kA · Up 1.25kV · Uoc 20kV

Request a Wholesale Quotation

Type 1+2+3 combined · 3 classes in one · MOQ quoted per configuration

3 classes in one
Up 1.25kV
4 Iimp steps
Product Details
  • IEC class — Combined Type 1+2+3 to IEC 61643-11
  • Uc — 255 / 275 VAC (L-N), 255 VAC (N-PE)
  • Iimp — 6.25 / 8 / 12.5 / 25 kA at 10/350 µs
  • In — 6.25 / 8 / 12.5 / 25 kA at 8/20 µs
  • Up — ≤1.25 kV, 1.5 kV on the N-PE path
  • Uoc — 20 kV combination test
  • Application — main boards, single-stage whole-building protection
Category:

The LT-T15/B+C is a Type 1+2+3 combined SPD rated 12.5kA Iimp (10/350 µs) that covers three protection stages in one 1P+NPE assembly. It is specified where a main board has to be protected but there is no room, or no budget, for a Type 1 device followed by a separate Type 2 and Type 3 stage. Clamping is ≤1.25kV L-N.

SPD Type 1+2+3 12.5kA: Three Stages in One Device

One Device Instead of a Chain

A conventional three-class design needs a Type 1 at the entry, a Type 2 at the sub-main and a Type 3 at the equipment, with cable lengths chosen to co-ordinate them. A B+C combined device collapses that chain into one component whose internal co-ordination has already been tested, which removes the part of the design most often done badly.

Four Iimp Steps on One Platform

The same body carries 6.25, 8, 12.5 and 25kA versions, allowing a project to match the exposure of each building without changing the panel layout or the installation method. The 12.5kA step is the most commonly specified.

1.25kV Clamping Across Three Classes

Combined devices sometimes compromise on clamping to cover three duties; this one holds 1.25kV on the phase paths and 1.5kV on the neutral-earth path, which is a fine-protection level rather than a distribution-board compromise.

A 20kV Combination Test

The Uoc 20kV figure comes from the combination wave test used for Type 3 devices, and it is what justifies the third class in the rating. Without it, a device carrying a Type 3 claim has no evidence behind the claim.

Specifications

Series LT-T15/B+C combined B+C surge protective device
IEC classification Type 1+2+3 combined, tested to IEC 61643-11
Maximum continuous voltage Uc 255 / 275 VAC L-N, 255 VAC N-PE
Impulse discharge current Iimp 6.25 / 8 / 12.5 / 25 kA (10/350 µs)
Nominal discharge current In 6.25 / 8 / 12.5 / 25 kA (8/20 µs)
Voltage protection level Up ≤1.25 kV L-N, ≤1.5 kV N-PE
Combination test Uoc 20 kV
Configurations 1P, 1P+NPE, 2P, 3P, 3P+NPE, 4P
Voltage codes 275V and 350V, with 690V and 760V variants for industrial supplies
Mounting 35mm DIN rail to EN 60715
Related models LT-T25/B+C (25kA class), LT-T25 (pure Type 1), LT-7T (compact 7kA)

Reading the LT-T15/B+C specification

The three-class claim is verified by a combination test, not by adding three labels to one module. The unit is tested with the 10/350 waveform for the Type 1 duty, the 8/20 waveform for Type 2, and the combination wave for Type 3, and the 1.25kV clamping level applies across all three. That is what allows a single device to sit at the main board and still be accepted as terminal protection in a compact installation.

Iimp is available in four steps on the same platform — 6.25, 8, 12.5 and 25kA — so a project can move up the range without changing the enclosure or the wiring diagram. The 12.5kA version on this page is the middle step.

Wiring Diagram & Connection

The LT-T15/B+C is a B+C assembly, so one unit carries the direct-strike stage and the distribution stage together. Wiring is a four-wire connection at the main board with a single earth return; the internal split does the rest.

LT-T15 B+C three class SPD wiring diagram for main distribution boards
LT-T15/B+C connection with the combined B and C paths shown per pole.

LT-T15/B+C — Removing the Weakest Part of the Design

Ask an installer what usually goes wrong with a staged surge protection design and the answer is co-ordination: two devices too close together, a Type 2 fitted where a Type 1 was needed, cable lengths guessed rather than measured. A combined device does not make the installer better, it removes the opportunity for that error, because the sequence happens inside a tested assembly.

What is lost is flexibility at the top end. A single device cannot be optimised separately for a 50kA lightning current and for fine protection, so the combined range tops out at 25kA while the dedicated gap devices reach 50kA. For most commercial and industrial buildings the 12.5kA or 25kA version covers the assessment, and the higher ratings exist for genuinely exposed sites.

LT-T15 B plus C combined Type 1 2 3 surge protector four-pole for main boards

Factory-Direct OEM / ODM Manufacturer

Tooling We Own, Standards We Follow

IEC 61643-11 platform · 250kA test station · OEM and ODM programmes

The modules on this page share a platform that has already passed type testing, so a variant order inherits that evidence instead of starting again. Manufacturing sits beside the laboratory, which is how we can verify a change before it enters a customer’s catalogue. Browse the rest of the range on AC SPD range.

  • Design control — drawings, BOM and test limits held under one quality system.
  • Lab access — impulse and residual-voltage checks run before a variant is released.
  • Branding — plate printing, laser marking and carton artwork prepared from your files.
  • Order size — sample lots, LCL and full containers all quoted from the same line.

LT-T15 B+C combined SPD — SPD production hall with totes ready for assembly

Buying Guide

Select the Iimp step from the risk assessment first, then confirm the voltage code and the pole arrangement.

  1. Take the required Iimp from the risk assessment and choose the nearest step: 6.25, 8, 12.5 or 25kA.
  2. Confirm the system voltage and whether the standard 275V or the 350V code applies.
  3. Select the pole arrangement, remembering the N-PE path in TT installations.
  4. Check that the single-stage approach suits the building; very large installations may still benefit from a downstream stage.
  5. Confirm the backup protection rating for the board fault level and order the documentation for the technical file.

Where the LT-T15/B+C is the wrong choice

It does not replace a Type 1 device where the risk assessment returns a high partial lightning current; above 25kA per pole the combined platform runs out of range and a dedicated Type 1 unit is required. Nor should it be used where the installation standard requires physically separate stages with a defined cable length between them — in that case a Type 1 device plus a Type 2 device is the compliant arrangement.

LT-T15 B+C combined SPD — automatic SPD production line running at LEITAI

How We Support Your Business

LT-T15 B+C combined SPD — automatic assembly turntable for SPD components

OEM / ODM

Learn more →

Housing colour, pole count, voltage window, alarm contact and retail packaging built on our standard SPD platform — your logo on the front, your reference on the side.


Custom marking · Private label · Own artwork

LT-T15 B+C combined SPD — operators assembling SPD modules on the LEITAI line

Wholesale

Learn more →

Factory-direct pricing with a per-item MOQ, mixing SPD models and backup protectors in one container for importers, panel builders and catalogue sellers.


Factory pricing · Mixed models · Container loading

LT-T15 B+C combined SPD — test instruments used for SPD quality control

Distributor Support

Learn more →

Account management, local voltage and standard advice, plus priority production slots for partners building an SPD range in their market.


Account manager · Market advice · Priority slots

Ready to Order the LT-T15/B+C?

Send the risk assessment result and the board details and we will confirm the LT-T15/B+C step that applies, with the voltage code and pole arrangement ready for the panel drawing.

Contact Our Sales Team

Frequently Asked Questions

What is a Type 1+2+3 combined SPD?

It is a single device tested against all three protection classes: the 10/350 lightning waveform, the 8/20 induced surge, and the combination wave used for terminal protection. It replaces a chain of three devices in compact boards.

Can one device really replace three stages?

Where the installation standard and the board layout allow a single point of protection, yes. Where the standard requires physical separation between stages, a combined device is not a substitute for a staged design.

What is the difference between 12.5kA and 25kA versions?

Charge capacity per pole. Both are Type 1+2+3 combined on the same platform; the higher rating is for entries with a greater calculated partial lightning current.

What is the Uoc 20kV figure for?

It is the combination wave test value behind the Type 3 claim. A device cannot be called Type 3 without it, so it is the evidence that the third class is real rather than nominal.

Which version suits a 690V or 760V industrial supply?

The range includes dedicated 690V and 760V codes for industrial supplies, which are used in wind turbine and box substation applications. Confirm the system voltage at quotation stage.

Does it need a separate Type 3 device at the equipment?

At 1.25kV the let-through is low enough for most equipment, so a separate Type 3 device is usually unnecessary unless the load has an unusually low withstand.

Cum sociis natoque penatibus

Purus in mollis nunc sed id semper risus. Velit laoreet id donec ultrices. Tellus pellentesque eu tincidunt tortor. Cum sociis natoque penatibus et. Vitae elementum curabitur vitae nunc sed velit. Nulla pellentesque dignissim enim sit amet venenatis urna cursus eget.

Mattis enim ut tellus elementum

Dolor morbi non arcu risus quis. Quisque non tellus orci ac auctor augue mauris augue. Ipsum a arcu cursus vitae congue mauris rhoncus aenean.

  • Cum sociis natoque penatibus et
  • Aliquam eleifend mi in nulla posuere
  • Ullamcorper malesuada proin libero
  • Purus in mollis nunc sed id

Reviews

There are no reviews yet.

Be the first to review “SPD Type 1+2+3 12.5kA Three-Stage — LT-T15/B+C”

Your email address will not be published. Required fields are marked *

Contact Us

Zhejiang Leitai Electrical Co., Ltd., a Chinese high-tech enterprise, focuses on R&D, production and sales of lightning protection products.

Tel: 0577-62625686

Mobile: 133 5337 7303

WhatsApp: +86 137 3677 5008

E-mail: leitai@leitai.cn

Address: No. 17, Zhenmin Road, Sibaiqiao Industrial Zone, Liushi Town, Wenxiang City, Zhejiang Province

Follow Us

Official Accounts