The LT-T15/B+C is a Type 1+2+3 combined SPD rated 12.5kA Iimp (10/350 µs) that covers three protection stages in one 1P+NPE assembly. It is specified where a main board has to be protected but there is no room, or no budget, for a Type 1 device followed by a separate Type 2 and Type 3 stage. Clamping is ≤1.25kV L-N.
SPD Type 1+2+3 12.5kA: Three Stages in One Device
One Device Instead of a Chain
A conventional three-class design needs a Type 1 at the entry, a Type 2 at the sub-main and a Type 3 at the equipment, with cable lengths chosen to co-ordinate them. A B+C combined device collapses that chain into one component whose internal co-ordination has already been tested, which removes the part of the design most often done badly.
Four Iimp Steps on One Platform
The same body carries 6.25, 8, 12.5 and 25kA versions, allowing a project to match the exposure of each building without changing the panel layout or the installation method. The 12.5kA step is the most commonly specified.
1.25kV Clamping Across Three Classes
Combined devices sometimes compromise on clamping to cover three duties; this one holds 1.25kV on the phase paths and 1.5kV on the neutral-earth path, which is a fine-protection level rather than a distribution-board compromise.
A 20kV Combination Test
The Uoc 20kV figure comes from the combination wave test used for Type 3 devices, and it is what justifies the third class in the rating. Without it, a device carrying a Type 3 claim has no evidence behind the claim.
Specifications
| Series | LT-T15/B+C combined B+C surge protective device |
|---|---|
| IEC classification | Type 1+2+3 combined, tested to IEC 61643-11 |
| Maximum continuous voltage Uc | 255 / 275 VAC L-N, 255 VAC N-PE |
| Impulse discharge current Iimp | 6.25 / 8 / 12.5 / 25 kA (10/350 µs) |
| Nominal discharge current In | 6.25 / 8 / 12.5 / 25 kA (8/20 µs) |
| Voltage protection level Up | ≤1.25 kV L-N, ≤1.5 kV N-PE |
| Combination test | Uoc 20 kV |
| Configurations | 1P, 1P+NPE, 2P, 3P, 3P+NPE, 4P |
| Voltage codes | 275V and 350V, with 690V and 760V variants for industrial supplies |
| Mounting | 35mm DIN rail to EN 60715 |
| Related models | LT-T25/B+C (25kA class), LT-T25 (pure Type 1), LT-7T (compact 7kA) |
Reading the LT-T15/B+C specification
The three-class claim is verified by a combination test, not by adding three labels to one module. The unit is tested with the 10/350 waveform for the Type 1 duty, the 8/20 waveform for Type 2, and the combination wave for Type 3, and the 1.25kV clamping level applies across all three. That is what allows a single device to sit at the main board and still be accepted as terminal protection in a compact installation.
Iimp is available in four steps on the same platform — 6.25, 8, 12.5 and 25kA — so a project can move up the range without changing the enclosure or the wiring diagram. The 12.5kA version on this page is the middle step.
Wiring Diagram & Connection
The LT-T15/B+C is a B+C assembly, so one unit carries the direct-strike stage and the distribution stage together. Wiring is a four-wire connection at the main board with a single earth return; the internal split does the rest.

LT-T15/B+C — Removing the Weakest Part of the Design
Ask an installer what usually goes wrong with a staged surge protection design and the answer is co-ordination: two devices too close together, a Type 2 fitted where a Type 1 was needed, cable lengths guessed rather than measured. A combined device does not make the installer better, it removes the opportunity for that error, because the sequence happens inside a tested assembly.
What is lost is flexibility at the top end. A single device cannot be optimised separately for a 50kA lightning current and for fine protection, so the combined range tops out at 25kA while the dedicated gap devices reach 50kA. For most commercial and industrial buildings the 12.5kA or 25kA version covers the assessment, and the higher ratings exist for genuinely exposed sites.

Factory-Direct OEM / ODM Manufacturer
Tooling We Own, Standards We Follow
IEC 61643-11 platform · 250kA test station · OEM and ODM programmes
The modules on this page share a platform that has already passed type testing, so a variant order inherits that evidence instead of starting again. Manufacturing sits beside the laboratory, which is how we can verify a change before it enters a customer’s catalogue. Browse the rest of the range on AC SPD range.
- Design control — drawings, BOM and test limits held under one quality system.
- Lab access — impulse and residual-voltage checks run before a variant is released.
- Branding — plate printing, laser marking and carton artwork prepared from your files.
- Order size — sample lots, LCL and full containers all quoted from the same line.

Buying Guide
- Take the required Iimp from the risk assessment and choose the nearest step: 6.25, 8, 12.5 or 25kA.
- Confirm the system voltage and whether the standard 275V or the 350V code applies.
- Select the pole arrangement, remembering the N-PE path in TT installations.
- Check that the single-stage approach suits the building; very large installations may still benefit from a downstream stage.
- Confirm the backup protection rating for the board fault level and order the documentation for the technical file.
Where the LT-T15/B+C is the wrong choice
It does not replace a Type 1 device where the risk assessment returns a high partial lightning current; above 25kA per pole the combined platform runs out of range and a dedicated Type 1 unit is required. Nor should it be used where the installation standard requires physically separate stages with a defined cable length between them — in that case a Type 1 device plus a Type 2 device is the compliant arrangement.
How We Support Your Business
OEM / ODM
Housing colour, pole count, voltage window, alarm contact and retail packaging built on our standard SPD platform — your logo on the front, your reference on the side.
Custom marking · Private label · Own artwork
Wholesale
Factory-direct pricing with a per-item MOQ, mixing SPD models and backup protectors in one container for importers, panel builders and catalogue sellers.
Factory pricing · Mixed models · Container loading
Distributor Support
Account management, local voltage and standard advice, plus priority production slots for partners building an SPD range in their market.
Account manager · Market advice · Priority slots
Ready to Order the LT-T15/B+C?
Send the risk assessment result and the board details and we will confirm the LT-T15/B+C step that applies, with the voltage code and pole arrangement ready for the panel drawing.
Frequently Asked Questions
What is a Type 1+2+3 combined SPD?
It is a single device tested against all three protection classes: the 10/350 lightning waveform, the 8/20 induced surge, and the combination wave used for terminal protection. It replaces a chain of three devices in compact boards.
Can one device really replace three stages?
Where the installation standard and the board layout allow a single point of protection, yes. Where the standard requires physical separation between stages, a combined device is not a substitute for a staged design.
What is the difference between 12.5kA and 25kA versions?
Charge capacity per pole. Both are Type 1+2+3 combined on the same platform; the higher rating is for entries with a greater calculated partial lightning current.
What is the Uoc 20kV figure for?
It is the combination wave test value behind the Type 3 claim. A device cannot be called Type 3 without it, so it is the evidence that the third class is real rather than nominal.
Which version suits a 690V or 760V industrial supply?
The range includes dedicated 690V and 760V codes for industrial supplies, which are used in wind turbine and box substation applications. Confirm the system voltage at quotation stage.
Does it need a separate Type 3 device at the equipment?
At 1.25kV the let-through is low enough for most equipment, so a separate Type 3 device is usually unnecessary unless the load has an unusually low withstand.