The LT-7T is a 7kA compact SPD combining Type 1, 2 and 3 duties in a single 1P+NPE module 36mm wide. It is specified where a small board — a kiosk substation, a pump house, a telecom cabinet — has to be protected but has no room for a staged design. Clamping is ≤1.25kV.
7kA Compact SPD Type 1+2+3 for Small Panels
Where a Staged Design Has Nowhere to Go
A kiosk substation, a small pump house or a compact retail board may have two spare rail positions and a requirement that, read literally, asks for three stages of protection. A three-in-one device is the only way to satisfy that without a new enclosure or a concession on the specification.
One-Pole-Plus-Neutral by Construction
The 1P+NPE format puts the phase-neutral and neutral-earth paths in one 36mm body, so a single-phase supply is fully covered by one device. That is the common intake arrangement for small installations and the reason the body is this size.
A 1.25kV Protection Level
Because the same element serves all three duties, the clamping voltage is competitive with a dedicated Type 2 or Type 3 device rather than being a compromise. That is the technical argument for accepting the reduced current capability: the let-through is genuinely low.
Limited Current, Stated Plainly
Seven kiloamps is modest compared with the main range, and it is honest about what it can do. This device suits small supplies with modest exposure; it is not a substitute for a 40kA or 80kA device on a building intake, and treating it as one is the mistake to avoid.
Specifications
| Series | LT-7T combined Type 1+2+3 surge protective device |
|---|---|
| IEC classification | Type 1+2+3 combined, tested to IEC 61643-11 |
| Maximum continuous voltage Uc | 255 VAC L-N and N-PE |
| Impulse discharge current Iimp | 7 kA (10/350 µs) |
| Nominal discharge current In | 7 kA (8/20 µs) |
| Voltage protection level Up | ≤1.25 kV |
| Configuration | 1P+NPE |
| Dimensions | 36 × 83mm |
| Mounting | 35mm DIN rail to EN 60715 |
| Application | small single-phase intakes, kiosk substations |
| Related models | LT-12.5T (12.5kA version), LT-T15/B+C for three-phase intakes |
Reading the LT-7T specification
The 7kA Iimp rating is deliberately modest, and that is the point: it matches the exposure of a small distribution point rather than a building intake. Where the risk assessment returns a higher partial lightning current, the LT-12.5T doubles the charge in the same footprint.
One module covers all three classes, which is what makes the 36mm width possible. The trade-off is that the device cannot be upgraded stage by stage later — the protection level and the rating are fixed together at order.
Wiring Diagram & Connection
The LT-7T covers Type 1, 2 and 3 duties in a 36 by 83 mm housing, so the intake of a small substation needs one unit and one earth connection. The diagram shows the combined L-N and N-PE paths inside the same enclosure.

- One unit per phase pair; a three-phase intake needs three of them
- Earth terminal is shared, so a single conductor runs to the intake earth bar
- Fits where a conventional two-stage arrangement has no rail space
LT-7T — Compact Protection Without a Concession
The usual argument against combined devices is that they compromise all three duties. That is true at high currents, where optimising an element for a lightning waveform and for fine protection genuinely pulls in two directions. At seven kiloamps the elements can be arranged so that both behaviours hold, and the 1.25kV protection level is the evidence.
What the buyer gives up is capacity, not quality. On a small single-phase intake with a short service cable and no particular exposure, seven kiloamps of lightning current is proportionate, and the alternative, a three-stage arrangement, may not physically fit. The honest framing is that this device is specified for small installations, not downsized from large ones.

Factory-Direct OEM / ODM Manufacturer
One Line, One Supplier
Own tooling · own test station · 40+ export markets since 2010
Importers usually buy surge protection from two or three traders and then discover that the modules do not fit the same busbar. We build the whole chain — moulding, assembly, calibration and final test — in one plant, so a mixed order arrives consistent. The series overview is on our AC SPD range page.
- OEM / ODM — design changes handled in house from drawing to first article.
- Mixed containers — several models and accessories loaded together against one PO.
- Documents — test reports, declarations and dimension drawings supplied with the shipment.
- After-sales — replacement modules and spare parts supported for the life of the range.

Buying Guide
- Confirm the supply is single-phase with a distributed neutral, which is the arrangement the 1P+NPE body serves.
- Check the rail space and the enclosure depth available for a 36 by 83mm device.
- Verify the exposure of the site is modest; a three-in-one device is not a substitute for a high-current entry unit.
- Confirm the 255V continuous voltage suits the system, particularly where the supply runs high.
- Plan the earth connection to the shortest practical route from the device to the earth bar.
Where the LT-7T is the wrong choice
It is not suitable for a main building intake where the calculated Iimp exceeds 7kA per pole, and it does not replace a staged design where the installation standard requires physical separation between protection classes. For a three-phase intake, the LT-T15/B+C is the three-phase equivalent.
How We Support Your Business
OEM / ODM
From a printed logo on a standard module to a modified housing and a new rating label — changes are handled on our own tooling, not through a broker.
Logo printing · Modified housing · Own label
Wholesale
Buy the models that move in your market and mix them with accessories in the same shipment; pricing is quoted per configuration.
Per-item MOQ · Mixed shipment · Export packing
Distributor Support
Stock planning, replacement-module supply and market-specific documentation for channel partners who hold inventory.
Stock planning · Spares · Documentation
Ready to Order the LT-7T?
Send a photo of the intake enclosure and the supply details and we will confirm whether the LT-7T fits the space and the duty, or whether the larger LT-12.5T is the better match.
Frequently Asked Questions
What is a Type 1+2+3 SPD in one module?
It is a single device tested against the lightning waveform, the induced surge waveform and the combination wave used for terminal protection, so it can serve as the only protective device in a small installation.
Where is a 7kA device appropriate?
At small distribution points with limited exposure: kiosk substations, pump houses, telecom cabinets and similar enclosures where a staged design will not fit.
Can it protect a whole building?
Only a small one with low exposure. A main intake with a higher calculated partial lightning current needs a larger Type 1 rating and, normally, a separate Type 2 stage.
Does the compact body compromise the protection level?
No, that is the point of the design. The 1.25kV figure is competitive with dedicated devices of similar capacity, and it is the reason the product can replace a staged arrangement.
Can it be used in a three-phase installation?
Not directly. The 1P+NPE configuration serves single-phase supplies. Three-phase intakes are served by the LT-T15/B+C or the LT-12.5T, depending on current.
Is a backup fuse required?
The device relies on the upstream protection of the intake. Where that protection is larger than the recommended value, a local device should be provided.