Single Phase Surge Protector 12.5kA — LT-12.5T

LT-12.5T — Higher Current Three-In-One SPD

The larger member of the compact three-in-one pair: 12.5kA of 10/350 lightning current and 12.5kA nominal at 8/20, with a 1.5kV protection level in the same 36 by 83mm body. For kiosk substations and small distribution points with a higher exposure than the LT-7T covers.

Model

✓

LT-12.5T SPD product photo

LT-12.5T Combined Type 1+2+3 Surge ProtectorType 1+2+3 · Iimp 12.5kA · In 12.5kA · Up 1.5kV

Request a Wholesale Quotation

Type 1+2+3 combined · Iimp 12.5kA · MOQ quoted per configuration

Iimp 12.5kA
3 types in one
Up 1.5kV
Product Details
  • IEC class — Combined Type 1+2+3 to IEC 61643-11
  • Uc — 255 VAC (L-N and N-PE)
  • Iimp — 12.5 kA at 10/350 µs
  • In — 12.5 kA at 8/20 µs
  • Up — ≤1.5 kV
  • Dimensions — 36 × 83mm, 1P+NPE
  • Application — kiosk substations, small distribution points
Category:

The LT-12.5T is a single phase surge protector rated 12.5kA Iimp (10/350 µs) for kiosk substations and single-phase distribution points. It uses the same 1P+NPE footprint as the LT-7T but nearly doubles the charge capacity, with a clamping level of ≤1.5kV.

Single Phase Surge Protector 12.5kA for Kiosks

Nearly Double the Charge of the Compact Base Model

The step from seven to twelve and a half kiloamps is the difference between a small retail intake and a kiosk substation that sits on the end of an overhead feeder. Both are single-phase, both have limited cabinet space, and the exposure is what separates them.

The Same Footprint

Because the body, terminals and mounting are shared with the smaller version, a specification can move up a rating without changing the enclosure. That is the practical value of the pair: one detail drawing covers both ratings.

Protection Level Trades Against Current

At 1.5kV this version clamps slightly higher than the 7kA model. The trade is deliberate and it is worth stating: more energy handling costs a little clamping performance, which is why the choice between the two is made on exposure rather than on convenience.

For Distribution Points Rather Than Buildings

Kiosk substations, small pumping stations, irrigation points and roadside cabinets share a pattern: limited space, an exposed supply and equipment that matters to the operator. A three-in-one device is often the only protection that fits, and at this rating it is proportionate.

Specifications

Series LT-12.5T combined Type 1+2+3 surge protective device
IEC classification Type 1+2+3 combined, tested to IEC 61643-11
Maximum continuous voltage Uc 255 VAC L-N and N-PE
Impulse discharge current Iimp 12.5 kA (10/350 µs)
Nominal discharge current In 12.5 kA (8/20 µs)
Voltage protection level Up ≤1.5 kV
Configuration 1P+NPE
Dimensions 36 × 83mm
Mounting 35mm DIN rail to EN 60715
Application kiosk substations, small exposed distribution points
Related models LT-7T (7kA version), LT-T25 (25kA Type 1+2)

Reading the LT-12.5T specification

The step from 7kA to 12.5kA is a step in charge, not in size. Both devices occupy the same rail width and use the same terminal arrangement, so a specification can move up the range without changing the enclosure — which matters in a kiosk where the DIN rail length is fixed by the manufacturer.

Clamping rises from 1.25kV to 1.5kV as the rating increases. That is the normal trade in a combined device: more charge capacity costs protection level, and the two figures have to be read together rather than compared in isolation.

Wiring Diagram & Connection

The LT-12.5T is the higher-current version of the compact three-in-one and is wired in the same way. Its 12.5 kA Iimp makes it the usual choice for a kiosk substation feeding a small LV board rather than a single piece of equipment.

LT-12.5T 12.5kA three-in-one SPD wiring diagram for kiosk substations
LT-12.5T wiring in a compact substation intake, 1P+NPE.

LT-12.5T — A Kiosk Substation in One Rail Position

Kiosk substations and roadside cabinets are a difficult specification: the enclosure is small, the supply arrives overhead, and there is no room for a three-stage design even when the standard would ask for one. A three-in-one device at twelve and a half kiloamps answers that combination directly, and it does so in a single rail position.

The decision between this and the LT-7T is made on the supply route rather than the load. A short underground service into a shop does not need the larger rating; an overhead feeder into a cabinet on a pole does. Where the answer is genuinely unclear, the larger rating is the safer choice, because the cost difference is small and the consequence of under-specifying is a device that operates more often than it should.

LT-12.5T compact Type 1+2+3 surge protector for small substation and kiosk boards

Factory-Direct OEM / ODM Manufacturer

One Line, One Supplier

Own tooling · own test station · 40+ export markets since 2010

Importers usually buy surge protection from two or three traders and then discover that the modules do not fit the same busbar. We build the whole chain — moulding, assembly, calibration and final test — in one plant, so a mixed order arrives consistent. The series overview is on our AC SPD range page.

  • OEM / ODM — design changes handled in house from drawing to first article.
  • Mixed containers — several models and accessories loaded together against one PO.
  • Documents — test reports, declarations and dimension drawings supplied with the shipment.
  • After-sales — replacement modules and spare parts supported for the life of the range.

LT-12.5T three-in-one SPD — SPD assembly hall with automated lines at LEITAI

Buying Guide

Confirm the supply route and the enclosure before choosing between the two compact ratings.

  1. Establish whether the supply arrives overhead or underground, since that dominates the exposure at a small intake.
  2. Confirm the single-phase arrangement and the 255V continuous voltage suits the site.
  3. Check the enclosure depth for a 36 by 83mm device plus its terminal clearance.
  4. Decide between the 7kA and 12.5kA ratings on the basis of that exposure assessment.
  5. Keep the earth lead to the shortest practical route; in a small enclosure this is easy to get wrong.

Where the LT-12.5T is the wrong choice

It is a single-phase device, so it is not the right choice for a three-phase kiosk supply — the LT-T15/B+C covers that arrangement. It is also not intended for a building main intake, where the exposure and the required Iimp are normally higher.

LT-12.5T three-in-one SPD — instrument bench for SPD calibration and testing

How We Support Your Business

LT-12.5T three-in-one SPD — soldering cells used in surge protector production

OEM / ODM

Learn more →

From a printed logo on a standard module to a modified housing and a new rating label — changes are handled on our own tooling, not through a broker.


Logo printing · Modified housing · Own label

LT-12.5T three-in-one SPD — module assembly zone with operators at LEITAI

Wholesale

Learn more →

Buy the models that move in your market and mix them with accessories in the same shipment; pricing is quoted per configuration.


Per-item MOQ · Mixed shipment · Export packing

LT-12.5T three-in-one SPD — LEITAI quality certificates and award display

Distributor Support

Learn more →

Stock planning, replacement-module supply and market-specific documentation for channel partners who hold inventory.


Stock planning · Spares · Documentation

Ready to Order the LT-12.5T?

Tell us how the supply reaches the site and send a photo of the cabinet, and we will confirm which compact three-in-one rating fits and whether any downstream device is still needed.

Contact Our Sales Team

Frequently Asked Questions

What is a kiosk substation SPD?

It is a compact protective device for the distribution point inside a prefabricated kiosk, where rail space is limited and the supply is typically single-phase with a local earth reference.

Why does 12.5kA clamp higher than 7kA?

More charge capacity in the same body means a larger element, which raises the residual voltage. The two ratings trade against each other and should be read together.

Can it be used in a three-phase kiosk?

No. This is a 1P+NPE single-phase device; a three-phase supply needs a three-pole or 3P+NPE arrangement.

Can it be used inside a kiosk substation?

Yes, that is a primary application. The device mounts on DIN rail inside the cabinet and protects the auxiliary and distribution circuits.

What happens if the exposure is higher than expected?

The device operates more frequently and reaches end of life sooner. Where the site proves to be more exposed, moving to a Type 1+2 device with a higher Iimp is the correct response rather than replacing the same model.

Does it need a separate Type 3 device at the load?

For most small installations the 1.5kV level is adequate at the equipment. Very sensitive loads may still warrant a Type 3 device, which we can quote alongside.

Cum sociis natoque penatibus

Purus in mollis nunc sed id semper risus. Velit laoreet id donec ultrices. Tellus pellentesque eu tincidunt tortor. Cum sociis natoque penatibus et. Vitae elementum curabitur vitae nunc sed velit. Nulla pellentesque dignissim enim sit amet venenatis urna cursus eget.

Mattis enim ut tellus elementum

Dolor morbi non arcu risus quis. Quisque non tellus orci ac auctor augue mauris augue. Ipsum a arcu cursus vitae congue mauris rhoncus aenean.

  • Cum sociis natoque penatibus et
  • Aliquam eleifend mi in nulla posuere
  • Ullamcorper malesuada proin libero
  • Purus in mollis nunc sed id

Reviews

There are no reviews yet.

Be the first to review “Single Phase Surge Protector 12.5kA — LT-12.5T”

Your email address will not be published. Required fields are marked *

Contact Us

Zhejiang Leitai Electrical Co., Ltd., a Chinese high-tech enterprise, focuses on R&D, production and sales of lightning protection products.

Tel: 0577-62625686

Mobile: 133 5337 7303

WhatsApp: +86 137 3677 5008

E-mail: leitai@leitai.cn

Address: No. 17, Zhenmin Road, Sibaiqiao Industrial Zone, Liushi Town, Wenxiang City, Zhejiang Province

Follow Us

Official Accounts