The LT-80RT is an 80kA pluggable surge protective device for data and telecom rooms, with a replaceable cartridge and a clamping level of ≤1.8kV. It is specified where the protection point sits in a facility that cannot be shut down for maintenance, so the cartridge has to be exchanged live.
80kA Pluggable SPD for Data and Telecom Rooms
Cartridge Exchange Without Isolation
The advantage of a plug-in design is not the cartridge itself but the procedure it enables: the element is removed and replaced from the front while the base and its wiring stay in place. In a live data hall that removes the need to schedule a shutdown for a maintenance item.
Varistor and Gap Together
The element combines a metal oxide varistor with a gas discharge gap. The varistor clamps precisely and the gap takes the steep front of a fast transient, so the pair covers a wider range of waveforms than either alone without the leakage penalty of a pure gap device.
Two Base Heights
The base is available at 90mm and 83mm so the cartridge front lands level with adjacent breakers and metering. In a data centre cabinet the visual difference matters less than the busbar fit, and the base height is what decides that.
Protection Level Suited to Second-Stage Duty
At 1.8kV this device is a controlled second stage: it holds a lower clamping point than the high-current devices at the origin while keeping enough capacity to absorb what they let through. It is the middle of a three-stage design rather than either end.
Specifications
| Series | LT-80RT pluggable Type 2 surge protective device |
|---|---|
| IEC classification | Type 2 / Class II, tested to IEC 61643-11 |
| Maximum continuous voltage Uc | 275 / 385 / 440 VAC |
| Nominal discharge current In | 40 kA (8/20 µs) |
| Maximum discharge current Imax | 80 kA (8/20 µs) |
| Voltage protection level Up | ≤1.8 kV |
| Protective element | MOV with GDT support in a plug-in cartridge |
| Base heights | 90mm and 83mm |
| Configurations | 1P, 2P, 3P, 4P |
| Mounting | 35mm DIN rail with removable cartridge |
| Related models | LT-100RT (60/100kA, same base), LT-80 fixed module |
Reading the LT-80RT specification
Two elements share the housing: a varistor for the fast clamping and a gap for the high-energy duty. That combination is what brings Up down to 1.8kV while keeping In 40kA and Imax 80kA, which is unusual at this rating.
Two base heights are available so the front face lines up with the surrounding breakers, and the cartridge can be replaced without isolating the board. In a data room, that difference decides whether a failed device is replaced during a maintenance window or left until the next shutdown.
Wiring Diagram & Connection
The 80 kA module sits on a pluggable base with a choice of 90 mm or 83 mm height, so the wired base can be matched to the rail spacing before the modules arrive. Inside, the unit combines a varistor with a gap, which is why the diagram shows two elements per pole.

LT-80RT — Maintenance Without a Shutdown
The specification that matters in a data centre or a telecom site is rarely the discharge current. It is the maintenance procedure: who has to authorise it, whether the load has to come off, and how long the panel is out of service. A plug-in cartridge changes all three answers, because the part that fails is the part that comes out.
That is worth paying for in installations where protection is part of a service-level agreement. In an ordinary commercial board, a fixed module is cheaper and performs identically, so the choice should be made on the maintenance regime rather than on the catalogue rating. Both use the same electrical class, and both are rated 40kA nominal.

Factory-Direct OEM / ODM Manufacturer
Built Here, Labelled for You
Injection moulding · varistor grading · 100% routine test · private label
Because the mould, the varistor grading bench and the impulse generator all belong to the same company, a private-label run does not depend on a third party agreeing to change a tool. Tell us the model designation you sell under and we print, pack and test to that name. More configurations are listed under Type 2 SPD range.
- Private label — your brand on the front, your reference on the side, your language in the manual.
- Custom build — voltage window, pole layout, alarm contact and packaging format are open to change.
- Traceability — each carton carries the batch number that links back to its test record.
- Lead time — confirmed against the actual production schedule when the order is placed.

Buying Guide
- Confirm whether cartridges will be replaced live, since that determines whether a plug-in base is required.
- Select the base height to match the depth of the breakers and metering on the same rail.
- Confirm the voltage code and the resulting 1.8kV protection level against the downstream equipment.
- Check the pole arrangement against the earthing system.
- Add replacement cartridges to the spares holding so a failure does not wait on a shipment.
Where the LT-80RT is the wrong choice
It is not a substitute for a Type 1 device where the building has an external lightning protection system, and the 1.8kV clamping is still a second-stage figure — terminal equipment needs its own protection. Where live replacement is not required, the fixed LT-80 is cheaper.
How We Support Your Business
OEM / ODM
Send a drawing and we return a sample: pole count, voltage window, terminal style, marking and packaging are all open to change.
Sample first · Drawing to part · Own marking
Wholesale
Tiered pricing across the SPD range with flexible quantities per model, so a wholesaler can test a market before committing to a container.
Tiered pricing · Flexible qty · Test orders
Distributor Support
Application advice for local earthing systems, plus the test evidence needed to satisfy inspectors and consultants.
Application help · Test evidence · Inspections
Ready to Order the LT-80RT?
Tell us the maintenance regime and the cabinet layout and we will confirm whether the plug-in LT-80RT or the fixed LT-80 is the better buy, with the base height and cartridge quantity to match.
Frequently Asked Questions
Why use a pluggable SPD in a data room?
Because the room cannot be shut down for a cartridge change. A pluggable device allows the failed element to be replaced live, without isolating the board.
What does the varistor plus gap combination do?
The varistor clamps quickly and the gap handles high energy, which is how the device reaches 1.8kV Up while keeping an 80kA Imax rating.
Is 1.8kV low enough for servers?
It is a second-stage level. Server power supplies normally need a Type 3 device or an SPD built into the PDU to bring the residual down further.
Why combine a varistor with a gap?
The varistor provides precise clamping and the gap handles the steep front of fast transients and shares the energy. The combination covers a wider range of waveforms than a single element.
Why are there two base heights?
So the cartridge front lines up with adjacent devices on the rail. The 90mm and 83mm bases cover the common breaker and metering depths.
Is this suitable for a telecom site?
Yes, and for data centres and traction cabinets. Those are the applications that benefit most from cartridge exchange without rewiring.