The LT-T25/B+C 690V is a Type 1+2 combined surge protection device for supplies above ordinary low voltage: wind turbine nacelles, heavy plant and industrial systems running at 690V or 760V. It keeps the 25kA Iimp rating of the standard version and raises the maximum continuous voltage to suit the higher system voltage.
690V Surge Protection Device for Wind Turbines
Built for Supplies Above Ordinary LV
Wind turbine converters, box substations and mining distribution often operate at 690V or 760V, which is outside the window of a standard 275V or 440V device. This version carries the same combined Type 1+2 platform into that voltage range without asking the installer to stack devices in series.
A 50kA Short-Circuit Withstand
The fault levels in converter cabinets and mining supplies are higher than in commercial boards, which is why this version is rated at 50kA rather than the 25kA of the low-voltage unit. That figure decides whether the device survives an end-of-life failure intact.
Three-Pole by Application
690V converter supplies are typically three-wire, so the three-pole configuration is the standard build. Where a neutral is present, a four-pole arrangement can be supplied and we confirm it against the system drawing.
Vibration and Cycling in Mind
Turbine cabinets impose thermal cycling and vibration on everything inside them. The terminal arrangement and internal fixing of this version are specified with that in mind, which is why it is offered as a distinct product rather than a voltage variant of a general-purpose device.
Specifications
| Series | LT-T25/B+C 690V combined Type 1+2 surge protective device |
|---|---|
| IEC classification | Type 1+2 combined, tested to IEC 61643-11 |
| Maximum continuous voltage Uc | 690 / 760 VAC |
| Impulse discharge current Iimp | 25 kA (10/350 µs) |
| Nominal discharge current In | 25 kA or 50 kA depending on version |
| Maximum discharge current Imax | 50 kA or 120 kA depending on version |
| Voltage protection level Up | ≤2.0 kV |
| Short-circuit withstand Iscwr | 50 kA |
| Configurations | 3P standard, 4P on request |
| Mounting | 35mm DIN rail to EN 60715 |
| Related models | LT-T25/B+C 440V (low voltage version), LT-T15/B+C 690V (three-class) |
Reading the LT-T25/B+C 690V specification
A 690V supply cannot use a 440V device, and the mistake is common enough that it is worth stating plainly: Uc must sit above the highest sustained voltage the system can produce, including regulation tolerance and the effects of regenerative operation. The 690/760V codes cover the two common wind and heavy-plant voltages.
The three-pole configuration is standard because the application is a three-phase supply without a distributed neutral. Vibration and thermal cycling matter more here than in a building board, which is why the terminal and housing design follows the same platform used in traction cabinets.
Wiring Diagram & Connection
The 690 V version is wired the same way as the 440 V unit but sits in a different system: the phase-to-phase voltage is 690 V and the neutral may be absent, so the diagram shows the three-phase connection without a neutral cartridge.

LT-T25/B+C 690V — Where the System Voltage Rules Out the Standard Device
A 690V converter supply is not simply a higher voltage version of a 400V board. The continuous voltage window, the fault level and often the physical arrangement all differ, and a device designed for 440V cannot simply be applied with a note on the drawing. This version exists because that gap is real and common in wind and mining work.
The 50kA short-circuit withstand is the detail that distinguishes it from the low-voltage version, and it reflects the fault levels found in converter cabinets. It is also the figure most often overlooked in specifications copied from a commercial building project, which is why we ask for the fault level rather than assuming it.

Factory-Direct OEM / ODM Manufacturer
Your Specification, Our Production Line
Type-tested platform · private-label marking · batch test records
We quote from a real production schedule, not from a stock list, which is why a customer changing from a competitor’s module to ours usually keeps the same panel layout and only changes the label. Everything needed for that switch — drawings, curves and test sheets — is available before the order. The wider family is on AC SPD range.
- Pre-order pack — datasheet, dimension drawing and declaration for your technical file.
- Branding — printed fronts, side references and instruction sheets in your language.
- Consistency — same platform across the range keeps panel stock simple for your customers.
- Support — a named contact for repeat orders and technical questions.

Buying Guide
- Confirm the nominal and maximum system voltage, distinguishing between 690V and 760V systems.
- Obtain the prospective fault current at the cabinet, since it determines whether the 50kA withstand is required.
- Confirm the pole arrangement from the system drawing, noting whether a neutral is distributed.
- Check the cabinet environment for temperature and vibration, and tell us if it is a turbine application.
- Confirm the backup protection rating for the higher fault level rather than reusing a low-voltage figure.
Where the LT-T25/B+C 690V is the wrong choice
It is not a substitute for a 440V device on an ordinary 400V board — the higher Uc raises the clamping level and gives away protection margin for no benefit. Where the system is a standard three-phase four-wire supply, the standard LT-T25/B+C is the correct choice.
How We Support Your Business
OEM / ODM
We print your brand on the module front and pack to your carton design; ODM covers new pole layouts, alternative voltage windows and signalling options.
Tooling in house · Branded packing · ODM design
Wholesale
Volume pricing on the whole LT range, with sample lots for tender packages and full containers for stock orders.
Bulk pricing · Samples · Firm lead times
Distributor Support
Technical files, selection curves and local standard guidance so your sales team can specify the right type on the first visit.
Datasheets · Selection help · Training
Ready to Order the LT-T25/B+C 690V?
Send the converter or box substation drawing with the system voltage and fault level, and we will confirm the 690V or 760V code and the pole arrangement for the cabinet.
Frequently Asked Questions
What is a 690V SPD used for?
It protects equipment on supplies above ordinary low voltage: wind turbine systems, heavy plant and industrial installations running at 690V or 760V. The higher Uc rating is what makes it suitable there.
Can a 440V SPD be used on a 690V system?
No. The maximum continuous voltage must exceed the highest sustained system voltage; a 440V device on a 690V supply would be operating beyond its rating.
Why is it three-pole?
The application is a three-phase supply without a distributed neutral, so the three phase paths plus the earth reference are what needs protecting. Four-pole versions are available on request.
Is it suitable for a wind turbine nacelle?
Yes, and the construction takes account of the thermal cycling and vibration found in that environment. Tell us the application at quotation stage so the documentation matches.
Does it come in a four-pole version?
A four-pole arrangement can be supplied where a neutral is distributed. Most 690V converter supplies are three-wire, so the three-pole version is standard.
What protection level does it give?
Up to 2.0kV. That is a first-stage figure, and sensitive control electronics downstream still benefit from a second-stage device.