The LT-40E is a 40kA neutral bonding SPD cartridge in the yellow housing, electrically identical to the LT-40D and intended where the client’s colour scheme requires a different identifier for the N-PE device. Ratings are In 20kA, Imax 40kA and Up ≤1.3kV on the N-PE path.
Neutral Bonding SPD Cartridge 40kA Dual Mode
Colour Schemes Differ Between Clients
Board identification conventions are not universal. Some operators mark the neutral-earth device in orange, others in yellow, and a third group uses the colour to separate protection stages rather than paths. Offering the same module in two colours keeps a client’s existing scheme intact instead of forcing a drawing change.
Identical Electrical Behaviour
Because the internal build is shared with the orange version, a project can use both colours without a technical review: 20kA nominal, 40kA maximum, 1.5kV across phase-neutral, 1.3kV across neutral-earth, and the same 18mm footprint.
One Rail Position for Two Paths
The argument for the dual-mode body is space, and it applies to this colour as much as the other. In a compact board with two free positions, a single module covers the neutral-earth path that would otherwise be left out of the design.
Stocked Alongside the Standard Range
The device shares its varistor family and thermal disconnector with the rest of the LT-40 line, so it appears in the same test records and the same spare-parts list as the phase modules it sits beside.
Specifications
| Series | LT-40E dual-mode Type 2 SPD |
|---|---|
| IEC classification | Type 2 / Class II, tested to IEC 61643-11 |
| Maximum continuous voltage Uc | 275 VAC L-N, 255 VAC N-PE |
| Nominal discharge current In | 20 kA (8/20 µs) |
| Maximum discharge current Imax | 40 kA (8/20 µs) |
| Voltage protection level Up | ≤1.5 kV L-N, ≤1.3 kV N-PE |
| Protection modes | L-N and N-PE combined |
| Module width | 18mm |
| Housing colour | yellow, for position identification |
| Mounting | 35mm DIN rail to EN 60715 |
| Related models | LT-40D (orange, same ratings), LT-40 (separate phase modules) |
Reading the LT-40E specification
Colour is the only difference from the LT-40D, and that is a real requirement rather than a cosmetic one: several utilities and panel builders use colour to distinguish the neutral-earth device from the phase modules, and a mixed-colour board is a maintenance error waiting to happen.
The electrical figures are the same: Uc 275V L-N and 255V N-PE, In 20kA, Imax 40kA, Up ≤1.5kV L-N and ≤1.3kV N-PE. Choosing between the two models is a specification decision, not a performance one.
Wiring Diagram & Connection
The LT-40E is the yellow member of the pair and is wired identically to the LT-40D. The colour split exists so that a panel with both phase and neutral paths carries an obvious visual code for the commissioning engineer.

LT-40E — Same Protection, a Different Site Convention
Buyers occasionally ask why two otherwise identical devices exist. The answer is in the panels themselves: a maintenance contractor working across several client estates meets a different colour convention in each one, and a manufacturer that only offers one colour effectively asks the client to change their scheme or to abandon the product.
Practically, this matters most in retrofit work. Replacing a failed neutral-earth module in a board wired to a yellow convention, with a device that matches the surrounding identification, avoids a note on the drawing and a question at the next inspection. The electrical specification is unchanged from the orange version, so the choice costs nothing in performance.

Factory-Direct OEM / ODM Manufacturer
We Manufacture, You Brand
Module moulding in house · MOV selection and thermal parts · OEM branding
Every LT component on this page — housing, busbar, varistor stack and thermal disconnector — is produced and assembled at our own plant in Liushi, Zhejiang, which is why a special voltage, pole count or marking requirement costs you a production slot rather than a new supplier qualification. The full AC range sits on our Type 2 SPD range page.
- OEM branding — logo, model number and rating text printed on the module front and the carton.
- ODM options — housing colour, pole count, voltage window, remote-signal contact and retail packing.
- Testing — residual voltage and thermal trip checked on every unit, records kept per batch.
- MOQ — quoted per configuration — mixed models can share one container.

Buying Guide
- Check the site convention for the neutral-earth position before ordering, since the two colours are otherwise identical.
- Confirm the earthing system and whether an N-PE device is required at that board.
- Verify the available rail space for an 18mm module plus the phase protection beside it.
- Confirm the protection level requirement for the neutral-earth path against the downstream equipment.
- Include the colour in the spare-parts description so future replacements match the board.
Where the LT-40E is the wrong choice
It does not replace phase modules, and the 275V L-N rating rules it out of 440V systems. Where the board uses a combined 3+1 arrangement with a single N-PE device, one cartridge is enough; where each phase needs its own module, the LT-40 is the correct line item.
How We Support Your Business
OEM / ODM
We print your brand on the module front and pack to your carton design; ODM covers new pole layouts, alternative voltage windows and signalling options.
Tooling in house · Branded packing · ODM design
Wholesale
Volume pricing on the whole LT range, with sample lots for tender packages and full containers for stock orders.
Bulk pricing · Samples · Firm lead times
Distributor Support
Technical files, selection curves and local standard guidance so your sales team can specify the right type on the first visit.
Datasheets · Selection help · Training
Ready to Order the LT-40E?
If your board scheme uses yellow for the neutral-earth position, tell us the quantities and the phase arrangement and we will quote the LT-40E together with the matching phase modules.
Frequently Asked Questions
What is the difference between the LT-40D and LT-40E?
Only the housing colour. The electrical ratings are identical; the colour identifies the N-PE device according to the client’s or utility’s scheme.
Can the two colours be mixed in one board?
Electrically yes, but it defeats the purpose of the colour coding. A board should use one convention consistently.
Is it a phase or neutral device?
It is the neutral-to-earth device, with a dual-mode element. Phase positions use the standard LT-40 modules.
Does this module protect a TT system adequately?
It provides the N-PE path that a TT system needs, which is often the missing element. Phase protection is still required alongside it.
Is it available with a remote contact?
Not in this body. For a monitored neutral-earth device, use the slim LT-40 with the YX suffix, which carries a volt-free contact in an 18mm module.
What is the lead time for a mixed order?
Both colours come from the same line, so a mixed order is quoted as one production slot. Exact lead time is confirmed against the schedule when the order is placed.