The LT-40D is a 40kA Type 2 N-PE surge arrester cartridge in an orange housing, covering the neutral-to-earth path with a dual-mode element. It is used where the N-PE gap has to be a separate module from the phase devices — common in TT systems and in boards where the phase and neutral protection are ordered as different line items.
N-PE Surge Arrester Cartridge 40kA Dual Mode
Two Protection Paths, One Module
A conventional four-pole arrangement needs a separate N-PE device beside the phase modules, which costs a rail position and adds a second item to the schedule. The LT-40D puts both paths in one 18mm body, and the protection level is stated separately for each: 1.5kV between phase and neutral, 1.3kV between neutral and earth.
Colour as a Field Instruction
The orange housing is not decoration. On a board with a row of identical modules, the device with a different colour is the one an electrician checks first and the one that is not accidentally replaced by a phase module from the van. Colour coding removes an instruction that would otherwise live only on a drawing.
Suited to Compact Enclosures
Small distribution boards in shops, apartments and small plant rooms often have two free rail positions, not five. A dual-mode module protects both paths in the space normally needed for one, which is the difference between a compliant installation and an unprotected board.
Same Platform as the Standard Range
The device uses the same varistor and thermal disconnector technology as the LT-40 family, so mixing it into a board with standard modules does not introduce a second set of characteristics or a second spare part.
Specifications
| Series | LT-40D dual-mode Type 2 SPD |
|---|---|
| IEC classification | Type 2 / Class II, tested to IEC 61643-11 |
| Maximum continuous voltage Uc | 275 VAC L-N, 255 VAC N-PE |
| Nominal discharge current In | 20 kA (8/20 µs) |
| Maximum discharge current Imax | 40 kA (8/20 µs) |
| Voltage protection level Up | ≤1.5 kV L-N, ≤1.3 kV N-PE |
| Protection modes | L-N and N-PE combined |
| Module width | 18mm |
| Housing colour | orange, for position identification |
| Mounting | 35mm DIN rail to EN 60715 |
| Related models | LT-40E (yellow, same ratings), LT-40 (separate phase modules) |
Reading the LT-40D specification
Dual mode means the cartridge handles both the N-PE path and, where required, a phase-to-neutral duty, which is why one module can replace two separate elements in a compact board. Ratings are In 20kA and Imax 40kA, with Up ≤1.5kV L-N and ≤1.3kV N-PE.
Uc is 275V L-N and 255V N-PE. The lower N-PE figure is deliberate: the neutral-to-earth voltage is not the same as the phase-to-neutral voltage, and using a single 275V value for both paths would misstate the rating.
Wiring Diagram & Connection
The orange LT-40D carries both a phase-to-neutral and a neutral-to-earth path in one 18 mm base, so the wiring diagram shows a single unit doing the work of a phase module plus a separate N-PE module.

LT-40D — The Neutral-Earth Path in Eighteen Millimetres
The neutral-to-earth path is the part of a protection scheme that gets forgotten. In a TT system it carries the surge that arrives on the neutral, and without a device there the phase protection is working with one hand behind its back. Conventional practice adds a separate N-PE module; this product merges the two paths so the space argument disappears.
The residual voltage figures also differ between the two paths, which is a detail worth reading carefully: 1.3kV across neutral and earth, 1.5kV across phase and neutral. That asymmetry reflects the different elements used for each path, and it is why the two numbers are quoted separately rather than as a single headline figure.

Factory-Direct OEM / ODM Manufacturer
One Line, One Supplier
Own tooling · own test station · 40+ export markets since 2010
Importers usually buy surge protection from two or three traders and then discover that the modules do not fit the same busbar. We build the whole chain — moulding, assembly, calibration and final test — in one plant, so a mixed order arrives consistent. The series overview is on our Type 2 SPD range page.
- OEM / ODM — design changes handled in house from drawing to first article.
- Mixed containers — several models and accessories loaded together against one PO.
- Documents — test reports, declarations and dimension drawings supplied with the shipment.
- After-sales — replacement modules and spare parts supported for the life of the range.

Buying Guide
- Confirm the earthing system; in TT installations the N-PE path is essential and this module provides it.
- Count the remaining rail positions before choosing between a dual-mode module and separate phase and N-PE devices.
- Check the protection level requirement for the neutral-earth path against the equipment downstream.
- Keep the colour convention consistent across a project so orange always means neutral-earth.
- Confirm the backup protection rating for the board, since it applies to both paths in the module.
Where the LT-40D is the wrong choice
It is not a phase module. Where a board needs four phase paths protected, the LT-40 provides them; this cartridge covers the neutral-earth position. The 275V Uc also means it is not suitable for 440V systems without checking the configuration.
How We Support Your Business
OEM / ODM
From a printed logo on a standard module to a modified housing and a new rating label — changes are handled on our own tooling, not through a broker.
Logo printing · Modified housing · Own label
Wholesale
Buy the models that move in your market and mix them with accessories in the same shipment; pricing is quoted per configuration.
Per-item MOQ · Mixed shipment · Export packing
Distributor Support
Stock planning, replacement-module supply and market-specific documentation for channel partners who hold inventory.
Stock planning · Spares · Documentation
Ready to Order the LT-40D?
Tell us the earthing system and the rail space available in the board and we will confirm how many LT-40D modules are needed alongside the phase protection, with a mixed configuration quotation.
Frequently Asked Questions
What is an N-PE SPD?
It protects the neutral-to-earth path, which is a separate concern from phase-to-neutral protection. In TT systems and in boards with a distributed neutral, that path needs its own element.
What does dual mode mean?
The cartridge is rated for both the N-PE duty and a phase-to-neutral duty, so one module can serve either position depending on the configuration.
Why is the orange colour significant?
It is a field instruction: the colour identifies the N-PE device so it is not swapped with a phase module during maintenance.
Does it work in a TN-S system?
Yes, though the neutral-earth path carries less surge current in TN systems than in TT because the neutral is bonded at the origin. It is still specified where the board is remote from that bond.
Can it be used alone on a single-phase board?
It protects both the phase-neutral and neutral-earth paths of a single-phase circuit, which is exactly the arrangement in many small boards. Confirm the fault level so the backup protection is correctly rated.
Is a remote signal available?
This module indicates status visually. Where a monitoring contact is required in the same footprint, specify the slim LT-40 with the YX suffix.














Reviews
There are no reviews yet.