The LT-100RT is a 100kA swappable surge protective device for critical power sites, combining front-access cartridge replacement with In 60kA and Imax 100kA. It is specified where the board cannot be taken out of service and the energy at the point is high enough that a standard plug-in unit would be undersized.
100kA Swappable SPD for Critical Power Sites
High Capacity and Front Access Together
Choosing between a high-current device and a serviceable one used to be a real compromise: the big fixed modules handled more energy but had to be swapped out as a unit. This product puts 100kA on a plug-in base, so the compromise disappears at the ratings that critical sites actually specify.
One Base, Two Ratings
The base is shared with the LT-80RT, which means a site can stock one base type and two cartridge ratings, and a board can be uprated from 40kA to 60kA nominal by changing the cartridge rather than the assembly. That is a stock-keeping benefit that shows up over the life of a facility.
Two Kilovolts Is a First-Stage Figure
The protection level of 2.0kV places this device at the energy-absorbing end of the design. It is followed downstream by devices with a lower clamping point, and the pair is selected together rather than treating this unit as the complete answer for sensitive equipment.
For Sites That Cannot Take an Outage
Telecom sites, small data centres and process control rooms share a maintenance constraint: the work has to be done inside a window that the operation can tolerate. A cartridge that comes out from the front keeps that window short and the procedure simple.
Specifications
| Series | LT-100RT pluggable Type 2 surge protective device |
|---|---|
| IEC classification | Type 2 / Class II, tested to IEC 61643-11 |
| Maximum continuous voltage Uc | 275 / 385 / 440 VAC |
| Nominal discharge current In | 60 kA (8/20 µs) |
| Maximum discharge current Imax | 100 kA (8/20 µs) |
| Voltage protection level Up | ≤2.0 kV |
| Protective element | metal oxide varistor in plug-in cartridge |
| Base | shared with LT-80RT, 90mm and 83mm heights |
| Configurations | 1P, 2P, 3P, 4P |
| Mounting | 35mm DIN rail with removable cartridge |
| Related models | LT-80RT (40/80kA, same base), LT-100 fixed module, LT-160 wide body |
Reading the LT-100RT specification
The combination is the reason this model exists: high capacity and front access are usually traded against each other, because a large element needs a large housing. The RT platform puts the cartridge on the front face, so the 100kA stack can be changed without removing wiring.
Up is 2.0kV, lower than the fixed LT-100 at 3.0kV, which makes it usable closer to the load. In 60kA and Imax 100kA are unchanged from the fixed version, so the electrical duty is the same.
Wiring Diagram & Connection
The LT-100RT shares the LT-80RT base, so the wiring is unchanged when a panel is upgraded from 80 kA to 100 kA: the cartridge is simply exchanged. Only the upstream back-up protection has to be checked against the higher rating.

LT-100RT — When Downtime Costs More Than the Device
The economics of surge protection change with the site. In a warehouse, a failed protector waits for the next maintenance visit; in a data hall, the visit itself is the expensive part and the device is a rounding error. That is the calculation behind specifying a high-current plug-in device rather than the largest fixed module available.
There is a second benefit in the shared base. Facilities that standardise on one base and stock two cartridge ratings can respond to a change in load without a new panel drawing, and a spare cartridge on the shelf covers a failure at either rating. Over a ten-year life that is a quieter advantage than the headline rating, but a more useful one.

Factory-Direct OEM / ODM Manufacturer
Built Here, Labelled for You
Injection moulding · varistor grading · 100% routine test · private label
Because the mould, the varistor grading bench and the impulse generator all belong to the same company, a private-label run does not depend on a third party agreeing to change a tool. Tell us the model designation you sell under and we print, pack and test to that name. More configurations are listed under Type 2 SPD range.
- Private label — your brand on the front, your reference on the side, your language in the manual.
- Custom build — voltage window, pole layout, alarm contact and packaging format are open to change.
- Traceability — each carton carries the batch number that links back to its test record.
- Lead time — confirmed against the actual production schedule when the order is placed.

Buying Guide
- Establish the fault level at the board so the backup protection is correctly rated for this device.
- Confirm that front cartridge access is achievable with the panel door open and the busbar in place.
- Check the protection level requirement downstream and plan the second stage accordingly.
- Decide the base height to suit the adjacent breakers and metering.
- Order spare cartridges at the same time so replacement does not wait on a shipment.
Where the LT-100RT is the wrong choice
It is not needed where maintenance can be scheduled during a shutdown — the fixed LT-100 costs less for the same rating. It is also not a Type 1 device, and the 2.0kV level still requires a downstream stage for sensitive equipment.
How We Support Your Business
OEM / ODM
Send a drawing and we return a sample: pole count, voltage window, terminal style, marking and packaging are all open to change.
Sample first · Drawing to part · Own marking
Wholesale
Tiered pricing across the SPD range with flexible quantities per model, so a wholesaler can test a market before committing to a container.
Tiered pricing · Flexible qty · Test orders
Distributor Support
Application advice for local earthing systems, plus the test evidence needed to satisfy inspectors and consultants.
Application help · Test evidence · Inspections
Ready to Order the LT-100RT?
For critical sites, tell us the board rating, the maintenance window and the downstream equipment, and we will quote the LT-100RT with its base, spare cartridges and the co-ordinated second stage.
Frequently Asked Questions
What is a swappable SPD?
It is a device whose protective cartridge can be removed and replaced from the front of the panel without disconnecting the terminals or isolating the board.
Why is its Up lower than the fixed LT-100?
The RT platform uses a different element arrangement, which brings the residual voltage from 3.0kV down to 2.0kV at the same 60/100kA rating.
Where is it worth the extra cost?
At sites that cannot take an outage: data centres, hospitals, continuous-process plants and similar critical power installations.
Is it suitable for an ordinary commercial board?
It can be used, but a fixed 40kA device at lower cost is normally the correct specification. This rating is for high-exposure or high-criticality boards.
What backup protection is required?
A device at or below the maximum rating stated for the SPD at the board’s prospective fault current, or a dedicated SPD disconnector. We confirm the value with the quotation.
How are cartridges identified for replacement?
Each cartridge carries the model reference and rating on its face, and the base keeps the installation date in the panel documentation. Matching a cartridge to a base is visual.