The LT-SSD50X is a fuse-free disconnector for SPD back-up, rated 30kA Iimp with a 3A tripping threshold. It replaces the fuse that would otherwise sit in series with a Type 1 or Type 2 arrester, and it removes two problems at once: nuisance tripping after a surge, and the maintenance error of fitting the wrong fuse.
SPD Fuse 30kA Fuse-Free Disconnector
The Right Device Instead of a Guess
An SPD is normally protected by a fuse or breaker chosen by rule of thumb, and the rule is usually written for a different fault level from the one on site. A dedicated device removes the guess: it is selected against the SPD’s maximum backup rating rather than against a table.
No Nuisance Tripping After a Surge
A general-purpose MCB sees the surge current as an overcurrent and can trip, leaving the SPD disconnected and the installation apparently protected. This device passes 30kA of 10/350 without operating, which is the behaviour the SPD beside it needs.
3A Tripping Threshold
The 3A tripping current is chosen to clear a failed SPD element without being so sensitive that normal leakage or a modest surge opens it. That balance is what a general-purpose device cannot strike, because its curve was designed for cable protection.
Removes a Maintenance Error
When an SPD fuse blows, the replacement is often whatever is in the van. A dedicated device is labelled with its purpose, which makes an incorrect substitution much less likely and keeps the protection system valid after maintenance.
Specifications
| Series | LT-SSD SPD backup protection range |
|---|---|
| Function | dedicated short-circuit and backup protection for SPDs |
| Rated voltage Ue | 440 VAC |
| Impulse withstand Iimp | 30 kA (10/350 µs) without tripping |
| Tripping current It | 3 A |
| Configurations | 1P, 2P, 3P, 4P |
| Earthing systems | TN-S, TN-C, TT |
| Mounting | 35mm DIN rail to EN 60715 |
| Positioning | immediately upstream of the SPD |
| Related models | LT-SSD80 (80kA), LT-SSD160 (160kA) |
Reading the LT-SSD50X specification
The tripping threshold is what makes it selective. At 3A it ignores the surge current that passes during a event and trips only on a sustained fault current, which is the condition a backup device exists to clear. A conventional fuse of the same rating cannot make that distinction and eventually operates on surge fatigue.
Iimp 30kA is the impulse withstand, which has to be at least as high as the arrester it protects. The device is available in 1P to 4P and is mounted in series ahead of the SPD on the same rail.
Wiring Diagram & Connection
The LT-SSD50X is not a surge protective device: it is wired in series in front of one, in place of the circuit breaker or fuse that would otherwise be used for back-up. The drawing shows the disconnector between the busbar and the SPD’s line terminal.

LT-SSD50X — What Belongs in Front of a 30kA Class SPD
The backup protection of an SPD is decided by two numbers: the maximum rating the SPD permits, and the prospective fault current at the board. Get the first from the SPD datasheet, the second from the installation, and select a device that satisfies both. A fuse chosen by habit usually satisfies neither, and the failure is silent until an SPD reaches end of life.
The 30kA impulse withstand is what separates this from a breaker of similar current rating. It means the device carries the surge that operates the SPD without itself opening, so protection is still connected after an event. That single property is the reason the accessory exists rather than being a marketing refinement.

Factory-Direct OEM / ODM Manufacturer
Tooling We Own, Standards We Follow
IEC 61643-11 platform · 250kA test station · OEM and ODM programmes
The modules on this page share a platform that has already passed type testing, so a variant order inherits that evidence instead of starting again. Manufacturing sits beside the laboratory, which is how we can verify a change before it enters a customer’s catalogue. Browse the rest of the range on AC SPD range.
- Design control — drawings, BOM and test limits held under one quality system.
- Lab access — impulse and residual-voltage checks run before a variant is released.
- Branding — plate printing, laser marking and carton artwork prepared from your files.
- Order size — sample lots, LCL and full containers all quoted from the same line.

Buying Guide
- Read the maximum backup protection rating from the SPD datasheet you are installing.
- Obtain the prospective fault current at that board from the installation design.
- Choose the SSD rating that satisfies both, in this case the 30kA class for SPDs up to that withstand.
- Match the pole count to the SPD so the protector covers every protected path.
- Label the device clearly in the panel schedule so a future replacement is not substituted with an MCB.
Where the LT-SSD50X is the wrong choice
It is not a replacement for an MCB or a fused switch where the installation requires visible isolation, and it does not remove the need to calculate the prospective fault current — the disconnector has to be rated for it. Where a fuse is mandated by the local standard, this device cannot be substituted.
How We Support Your Business
OEM / ODM
Housing colour, pole count, voltage window, alarm contact and retail packaging built on our standard SPD platform — your logo on the front, your reference on the side.
Custom marking · Private label · Own artwork
Wholesale
Factory-direct pricing with a per-item MOQ, mixing SPD models and backup protectors in one container for importers, panel builders and catalogue sellers.
Factory pricing · Mixed models · Container loading
Distributor Support
Account management, local voltage and standard advice, plus priority production slots for partners building an SPD range in their market.
Account manager · Market advice · Priority slots
Ready to Order the LT-SSD50X?
Tell us which SPD you are installing and the fault level at the board, and we will confirm whether the LT-SSD50X is the correct backup device or whether a higher rating is required.
Frequently Asked Questions
What is an SPD backup fuse for?
It clears a sustained fault current through a failed SPD, which the upstream breaker may not detect. Without it, a faulted varistor can overheat or sustain an arc.
What does fuse-free mean?
The device trips on a sustained fault without a fuse element to replace, so it can be reset rather than re-fused. It also avoids fitting the wrong fuse rating.
Why is the tripping threshold 3A?
It is low enough to clear a fault current and high enough to ignore surge current, which is what prevents nuisance tripping after a lightning event.
Does it replace the need for a main breaker?
No. It sits immediately upstream of the SPD as its dedicated backup protection. The installation’s main protective devices remain as designed.
Which pole count should I choose?
Match it to the SPD. A 4P SPD takes a 4P disconnector so every protected path has backup protection.
Is it suitable for a TT system?
Yes, along with TN-S and TN-C. The device protects the SPD, and the earthing arrangement is handled by the SPD configuration.